{"id":1939,"date":"2019-10-22T06:08:55","date_gmt":"2019-10-22T06:08:55","guid":{"rendered":"http:\/\/jasubhaiengineering.com\/ees\/?page_id=1939"},"modified":"2019-10-22T06:37:17","modified_gmt":"2019-10-22T06:37:17","slug":"catalytic-thermal-oxidizers","status":"publish","type":"page","link":"https:\/\/jasubhaiengineering.com\/ees\/products-solutions\/catalytic-thermal-oxidizers\/","title":{"rendered":"Catalytic Thermal Oxidizers"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1569915157434{margin-bottom: 100px !important;}&#8221;][vc_column width=&#8221;3\/4&#8243;][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<strong>Catalytic oxidation for flexible waste gas streams<\/strong><\/p>\n<ul>\n<li>Incineration of <b>liquid, <\/b><b>solid <\/b><b>and <\/b><b>gaseous <\/b>waste streams<\/li>\n<li>Applicable for a <b>wide <\/b><b>range <\/b>of concentrations and compositions<\/li>\n<li>Technology <b>focuses<\/b> on:\n<ul>\n<li>Low Emissions<\/li>\n<li>High Availability and Reliability<\/li>\n<li>Recovery of Energy<\/li>\n<li>Recovery of Resources<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;1929&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]<strong>FEATURES OF CATALYTIC THERMAL OXIDIZERS (CTO)<br \/>\n<\/strong><\/p>\n<ul>\n<li>Raw gas stream with a medium heating value<\/li>\n<li>Very flexible is able to handle small or big stream.<\/li>\n<li>Lower operating Temperature.<\/li>\n<li>Applications in\n<ul>\n<li>Chemical Industry<\/li>\n<li>Oil and Gas Industry<\/li>\n<li>Textile Industry<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><strong>APPLICATION OF CTO<\/strong><\/p>\n<ul>\n<li>This technology is suitable for a wide range of gas streams with a medium heat value.<\/li>\n<li>It is based on the catalytic oxidation of VOC that allows its reaction at not more than 500\u00b0C. This is the working temperature in the catalyst bed;<\/li>\n<li>Only for start up and running conditions with low VOC concentrations, an electric heating unit supplies the necessary thermal energy in order to maintain the oxidation process on the catalyst.<\/li>\n<li>Tail gas concentration: On the catalyst bed the VOCs incinerate for more than 99,5 % to water and carbon dioxide.<\/li>\n<li>This solution offers flexible stream quantity, low running temperature and efficient energy recovery system.is suitable for big quantities of raw gas with low concentration of VOC.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/4&#8243;][stm_sidebar sidebar=&#8221;311&#8243;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;third_bg_color&#8221; css=&#8221;.vc_custom_1451889219674{margin-bottom: -60px !important;}&#8221;][vc_column][vc_cta h2=&#8221;Providing Turnkey Solutions in Combustion &amp; Environmental Technologies&#8221; h2_font_container=&#8221;font_size:20px|color:%23000000|line_height:24px&#8221; h2_use_theme_fonts=&#8221;yes&#8221; shape=&#8221;square&#8221; style=&#8221;flat&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;get in touch&#8221; btn_style=&#8221;flat&#8221; btn_color=&#8221;theme_style_2&#8243; btn_align=&#8221;right&#8221; btn_i_align=&#8221;right&#8221; btn_i_icon_fontawesome=&#8221;fa fa-chevron-right&#8221; use_custom_fonts_h2=&#8221;true&#8221; btn_button_block=&#8221;true&#8221; btn_add_icon=&#8221;true&#8221; el_class=&#8221;third_bg_color&#8221; css=&#8221;.vc_custom_1563529447340{margin-bottom: 0px !important;}&#8221;][\/vc_cta][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1569915157434{margin-bottom: 100px !important;}&#8221;][vc_column width=&#8221;3\/4&#8243;][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]Catalytic oxidation for flexible waste gas streams Incineration of liquid, solid and gaseous waste streams Applicable for a wide range of concentrations and compositions Technology focuses on: Low Emissions High Availability and Reliability Recovery of Energy Recovery of Resources [\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;1929&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]FEATURES OF CATALYTIC THERMAL OXIDIZERS (CTO) Raw gas<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1604,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":""},"class_list":["post-1939","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/pages\/1939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/comments?post=1939"}],"version-history":[{"count":4,"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/pages\/1939\/revisions"}],"predecessor-version":[{"id":1956,"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/pages\/1939\/revisions\/1956"}],"up":[{"embeddable":true,"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/pages\/1604"}],"wp:attachment":[{"href":"https:\/\/jasubhaiengineering.com\/ees\/wp-json\/wp\/v2\/media?parent=1939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}